Specification & Description
Specification | Description |
---|---|
Part Number | 3RP1505-1RW30 |
Manufacturer | Siemens |
Product Brand Name | SIRIUS |
Product Designation | Timing Relay |
Product Type Designation | 3RP15 |
Functions | 8 functions |
Time Ranges | 15 time ranges (0.05 s - 100 h) |
Contacts | 2 change-over contacts |
Contact Material | AgSnO2 |
Control Supply Voltage | 24-240 V AC/DC |
Control Supply Voltage Frequency | 50/60 Hz |
Protection Class IP | IP20 |
Mounting Type | Screw and snap-on mounting onto 35 mm standard mounting rail |
Mounting Position | Any |
Dimensions (W x H x D) | 22.5 x 102 x 91 mm |
Ambient Temperature (Operation) | -25 to +60 °C |
Ambient Temperature (Storage) | -40 to +85 °C |
Relative Humidity (Operation) | 10 to 95% |
Mechanical Service Life | 10,000,000 switching cycles |
Electrical Endurance | 100,000 switching cycles at AC-15 at 230 V |
Adjustable Time | 0.05 s to 100 h |
Thermal Current | 5 A |
Minimum ON Period | 35 ms |
Recovery Time | 150 ms |
Insulation Voltage | 300 V (overvoltage category III, pollution degree 3) |
Test Voltage for Isolation | 2 kV |
Surge Voltage Resistance | 4,000 V |
Shock Resistance | 11g / 15 ms (IEC 60068-2-27) |
Vibration Resistance | 10-55 Hz / 0.35 mm (IEC 60068-2-6) |
EMI Immunity | EN 61000-6-2 |
Conducted Interference | 2 kV network connection / 1 kV control connection (IEC 61000-4-4) |
Electrostatic Discharge | 4 kV contact discharge / 8 kV air discharge (IEC 61000-4-2) |
Field-bound Parasitic Coupling | 10 V/m (IEC 61000-4-3) |
Conductor Cross-section (Solid) | 0.5 - 4 mm² |
Conductor Cross-section (Stranded) | 0.5 - 2.5 mm² |
AWG Conductor Cross-section (Solid) | 20 - 14 |
AWG Conductor Cross-section (Stranded) | 20 - 14 |
Tightening Torque | 0.8 - 1.2 N·m |
Connection Screw Thread | M3 |
Required Spacing (Side-by-side Mounting) | 0 mm in all directions |
Installation Altitude | Up to 2,000 m above sea level |
Product Function | Removable terminal for auxiliary and control circuit |
Type of Electrical Connection | Screw-type terminals |
Conductor-bound Parasitic Coupling (Surge) | 1 kV (IEC 61000-4-5) |
Conductor-bound Parasitic Coupling (Burst) | 2 kV network connection / 1 kV control connection (IEC 61000-4-4) |
Field-bound Parasitic Coupling | 10 V/m (IEC 61000-4-3) |
Electrostatic Discharge | 4 kV contact discharge / 8 kV air discharge (IEC 61000-4-2) |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss | 2 W |
Reference Code (DIN EN 81346-2) | K |
Reference Code (DIN 40719) | K |
Category (EN 954-1) | None |
Protection Against Electrical Shock | Finger-safe |
Type of Insulation | Basic insulation |
Category (EN 954-1) | None |
Power Loss |
The Siemens 3RP1505-1RW30 is a versatile timing relay designed to meet the demands of various industrial automation applications. This multifunctional relay offers a wide range of timing functions, making it suitable for diverse operational requirements. It features two change-over contacts and supports eight different functions, providing flexibility in control and automation tasks.
With a robust design, the 3RP1505-1RW30 operates within a voltage range of 24 to 240V AC/DC at 50/60 Hz, ensuring compatibility with various power systems. The relay is equipped with positively driven and gold-plated contacts, enhancing reliability and longevity. It offers 15 selectable time ranges from 0.05 seconds to 100 hours, allowing precise control over timing operations.
The relay's compact dimensions (22.5 x 91 x 102 mm) and snap-on mounting capability make it easy to install in tight spaces and on standard 35 mm DIN rails. It is designed to operate in a wide temperature range from -25°C to +60°C, ensuring reliable performance in harsh environments.
The Siemens 3RP1505-1RW30 timing relay is an essential component for automation systems, providing accurate and reliable timing control for various industrial processes. Its high-quality construction and versatile functionality make it a valuable addition to any automation setup.
Commonly Asked Questions
Is my order covered by a warranty?
Marvo provides a full 12-month warranty on all products, whatever the condition. For your peace of mind, all parts are ‘Marvo Approved’ which means that they have been tested and checked to ensure that they are in working condition. If you are unhappy with the part(s) you received and would like to request a return, you can do so by completing our quick and easy online form. Once we have received your Returns Request, a member of the team will be in touch to discuss this further with you. You can read more about our warranty policy here.
Read more...What payment methods do you accept?
We accept card payments from all major credit, debit and Mastercard providers including Visa, American Express, Western Union, Paypal and bank transfers. Before you complete an order you will be prompted to input your payment details, at which point you can enter the relevant card information you wish to use for your transaction. If you are experiencing issues with your payment method then you can contact our team via email here. From there, you will be directed to the most relevant resource or person to help you complete your payment, get your order processed and ensure that your parts are on the way to your delivery address.
Read more...Is Marvo a credible parts supplier?
Marvo is a highly credible supplier of industrial automation parts and components with dedicated hubs around the world offering industry-leading products and services. Marvo is committed to providing a quick, easy and reliable place to source your automation and control components. All purchases come as standard with a comprehensive 12-month return to base warranty meaning that, in just a few clicks, you can source critical parts more seamlessly than ever before. Click here to read an article on how Marvo is redefining convenience for automation and manufacturing professionals.
Read more...Have steps been taken to ensure quality control?
Marvo takes pride in product quality and has put several measures in place to assure high levels of quality standards. For your peace of mind, all parts have been ‘Marvo Approved’ which means that they have been tested and checked to ensure that they are in working condition. Redefine convenience and secure priority delivery on all parts along with a comprehensive 12-month warranty. This is the smart new way to buy automation and control components.
Read more...How do I create an account?
Creating an account is incredibly simple and takes a matter of seconds. You can create a Marvo account at any time by clicking here and following the simple steps on screen. By creating a Marvo account you can store your contact details, delivery addresses, billing addresses and more, meaning that you can enjoy game-changing convenience faster than ever before.
Read more...Peace of mind with every purchase
Anna
‘I can recommend quick, efficient, and professional.’
Thomas Roland Geaughan
‘Prompt and expert service. Ease of access to find the parts I needed.’
Milan Kosík
‘Large selection of spare parts, fast delivery.’
Kayden
‘Services is great.’
Muswalin
‘Good packing, quickly delivery and responsible.’
Advance Lifts
‘Great customer service , we needed some assistance quickly and received it.’
Anna
‘I can recommend quick, efficient, and professional.’
Julien
‘Perfect quick delivery, good service.’
Milan Kosík
‘Large selection of spare parts, fast delivery.’
Similar Products
Our service to you
Lightning-Fast Express Shipping: Receive your order in record time with our express shipping options, ensuring you minimize downtime and keep your projects on track.
No-Risk Returns, Guaranteed: Return your parts anytime for a full refund. Our hassle-free return policy ensures you’re never stuck with something you don’t need.
Clear Pricing with No Hidden Fees: What you see is what you pay, transparent pricing with no extra costs, ever. Rest assured, all taxes and fees are already included in your final price.
Rock-Solid Reliability at a Fraction of the Cost: Get pre-owned electronic parts that are fully tested for peak performance, saving you money without compromising on quality, backed by a comprehensive warranty.
Frequently Asked Questions
What is the function of this timing relay?
This timing relay is designed to control the timing of electrical circuits, providing precise time delays for various industrial applications.
What voltage range does this timing relay support?
The Siemens 3RP1505-1RW30 timing relay supports a wide voltage range of 24 to 240V AC/DC at 50/60 Hz.
What are the dimensions of this timing relay?
The dimensions of the Siemens 3RP1505-1RW30 timing relay are 22.5 mm in width, 91 mm in depth, and 102 mm in height.
What type of mounting does this timing relay use?
This timing relay uses screw and snap-on mounting onto a 35 mm standard mounting rail.
What is the adjustable time range for this timing relay?
The adjustable time range for the Siemens 3RP1505-1RW30 timing relay is from 0.05 seconds to 100 hours.
What is the protection class of this timing relay?
The protection class of the Siemens 3RP1505-1RW30 timing relay is IP20.
What is the mechanical service life of this timing relay?
The mechanical service life of the Siemens 3RP1505-1RW30 timing relay is approximately 10 million switching cycles.
What type of contacts does this timing relay have?
The Siemens 3RP1505-1RW30 timing relay features positively driven and gold-plated relay contacts.
What is the thermal current rating of this timing relay?
The thermal current rating of the Siemens 3RP1505-1RW30 timing relay is 5 A.
What is the degree of pollution for this timing relay?
The Siemens 3RP1505-1RW30 timing relay has a degree of pollution rating of 3.
Part conditions explained
We want your buying experience to be as seamless as possible. So, here are all of the product descriptions you will see when browsing Marvo, explained a little further:
New unsealed: The product is in its original packaging, but the packaging has been opened or unsealed. It has never been used and should be in near pristine condition.
New sealed: The product is sealed in its original packaging. It has never been opened or used, ensuring that it's in an untouched state.
New unboxed: The product does not come in its original packaging, but it has never been used and is in great working condition.
Refurbished: The product has been previously used, but it has undergone a thorough refurbishment process to restore it to a like-new or functional condition. Any defects or issues have been addressed, making it suitable for reuse.
Used: The product has been previously owned and has been used. It may show signs of wear and tear but is still functional and operational. The condition may vary depending on the specific item and its usage history.