Part Number |
LC1D65AMD |
Manufacturer |
Schneider |
Range |
TeSys D |
Product Type |
Contactor |
Device Short Name |
LC1D |
Contactor Application |
Motor control, Resistive load |
Utilisation Category |
AC-1, AC-3 |
Poles Description |
3P (3 NO) |
Rated Operational Voltage |
<= 690 V AC 25...400 Hz (Power Circuit), <= 300 V DC (Power Circuit) |
Rated Operational Current |
80 A (<= 60 °C) at <= 440 V AC AC-1, 65 A (<= 60 °C) at <= 440 V AC AC-3 |
Motor Power kW |
30 kW at 380...400 V AC 50/60 Hz, 37 kW at 500 V AC 50/60 Hz, 37 kW at 660...690 V AC 50/60 Hz, 18.5 kW at 220...230 V AC 50/60 Hz |
Motor Power hp |
40 hp at 460/480 V AC 50/60 Hz (3-phase motors), 5 hp at 115 V AC 50/60 Hz (1-phase motors), 10 hp at 230/240 V AC 50/60 Hz (1-phase motors), 20 hp at 200/208 V AC 50/60 Hz (3-phase motors), 20 hp at 230/240 V AC 50/60 Hz (3-phase motors), 50 hp at 575/600 V AC 50/60 Hz (3-phase motors) |
Control Circuit Type |
DC standard |
Control Circuit Voltage |
220 V DC |
Auxiliary Contact Composition |
1 NO + 1 NC |
Rated Impulse Withstand Voltage |
6 kV conforming to IEC 60947 |
Overvoltage Category |
III |
Conventional Free Air Thermal Current |
80 A at <= 60 °C (Power Circuit), 10 A at <= 60 °C (Signalling Circuit) |
Rated Making Capacity |
1000 A at 440 V (Power Circuit) conforming to IEC 60947, 140 A AC (Signalling Circuit) conforming to IEC 60947-5-1, 250 A DC (Signalling Circuit) conforming to IEC 60947-5-1 |
Rated Breaking Capacity |
1000 A at 440 V (Power Circuit) conforming to IEC 60947 |
Rated Short-Time Withstand Current |
100 A 1 s (Signalling Circuit), 120 A 500 ms (Signalling Circuit), 140 A 100 ms (Signalling Circuit), 520 A <= 40 °C 10 s (Power Circuit), 900 A <= 40 °C 1 s (Power Circuit), 110 A <= 40 °C 10 min (Power Circuit), 260 A <= 40 °C 1 min (Power Circuit) |
Associated Fuse Rating |
125 A gG at <= 690 V coordination type 1 (Power Circuit), 125 A gG at <= 690 V coordination type 2 (Power Circuit), 10 A gG (Signalling Circuit) conforming to IEC 60947-5-1 |
Average Impedance |
1.5 mOhm at 50 Hz - Ith 80 A (Power Circuit) |
Rated Insulation Voltage |
600 V (Power Circuit) certifications CSA, 600 V (Power Circuit) certifications UL, 690 V (Power Circuit) conforming to IEC 60947-4-1, 690 V (Signalling Circuit) conforming to IEC 60947-1, 600 V (Signalling Circuit) certifications CSA, 600 V (Signalling Circuit) certifications UL |
Electrical Durability |
1.45 Mcycles 65 A AC-3 at Ue <= 440 V, 1.4 Mcycles 80 A AC-1 at Ue <= 440 V |
Power Dissipation per Pole |
6.3 W AC-3, 9.6 W AC-1 |
Protective Cover |
With |
Mounting Support |
Plate, Rail |
Standards |
EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2 No 14 |
Product Certifications |
CCC, CSA, GOST, UL |
Connections - Terminals |
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² (flexible with cable end), Power circuit: EverLink BTR screw connectors 1 cable(s) 1...35 mm² (flexible without cable end) |
Tightening Torque |
Control circuit: 1.7 N.m on screw clamp terminals with screwdriver flat Ø 6 mm, Power circuit: 5 N.m on EverLink BTR screw connectors cable <= 25 mm² hexagonal 4 mm, Power circuit: 8 N.m on EverLink BTR screw connectors cable 25...35 mm² hexagonal 4 mm |
Operating Time |
16...24 ms opening, 42.5...57.5 ms closing |
Coil Technology |
Built-in bidirectional peak limiting diode suppressor |
Control Circuit Voltage Limits |
0.1...0.3 Uc at 60 °C drop-out, 0.75...1.25 Uc at 60 °C operational |
Inrush Power in W |
19 W at 20 °C |
Hold-in Power Consumption in W |
7.4 W at 20 °C |
Auxiliary Contacts Type |
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
Signalling Circuit Frequency |
25...400 Hz |
Minimum Switching Current |
5 mA for signalling circuit |
Minimum Switching Voltage |
17 V for signalling circuit |
Non-overlap Time |
1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact) |
Insulation Resistance |
> 10 MOhm for signalling circuit |
IP Degree of Protection |
IP2x front face conforming to IEC 60529 |
Protective Treatment |
TH conforming to IEC 60068-2-30 |
Pollution Degree |
3 |
Ambient Air Temperature for Operation |
-5...60 °C |
Ambient Air Temperature for Storage |
-60...80 °C |
Permissible Ambient Air Temperature |
-40...70 °C at Uc |
Operating Altitude |
3000 m without derating in temperature |
Fire Resistance |
850 °C conforming to IEC 60695-2-1 |
Flame Retardance |
V1 conforming to UL 94 |
Mechanical Robustness |
Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor open 10 Gn for 11 ms, Shocks contactor closed 15 Gn for 11 ms |
Height |
122 mm |
Width |
55 mm |
Depth |
120 mm |
Product Weight |
0.935 kg |
Sustainable Offer Status |
Green Premium product |
RoHS |
Compliant since 0001 - Schneider Electric declaration of conformity |
REACh |
Reference not containing SVHC above the threshold |
Product Environmental Profile |
Available |
Product End of Life Instructions |
Need no specific recycling operations |